Skip to main content
Level 2
Sep 7, 2022 9:08 AM UTC
Solved

DITA OT: Adding Post Generation workflow to AEM Site output config, doesn't let the generation status to complete

I added a custom workflow model to the "post generation workflow" input of AEM SITE output config. After the I click the Generate button, the status of output never changes to complete. After manual verification, I see that the site output was generated correctly and the workflow was executed fine as well (workflow was marked COMPLETE and moved to achieve). However, the output console corresponding to the ditamap keeps on showing post-processing state and never finishes.

The workflow I used is very simple with only a process step which has just a logger statement inside.

I am not getting enough information for the API being triggered:

http://localhost:4502/bin/publishlistener?operation=PUBLISHBEACON&source=%2Fcontent%2Fdam%2Fdita-content%2Fen%2Fmyproject%2Fc2240%2Fmaps%2Fconfiguring-universal-paper-settings.ditamap&_=1662452045391

This post is no longer active and is closed to new replies. Need help? Start a new post to ask your question.
Vijendra1
Vijendra1Accepted solution
Adobe Employee
Sep 7, 2022 11:11 AM UTC

For any custom workflow for post generation, you need to add the last process step with process as "Finalize Post Generation" as shown in the figure

 

 

Thanks,

Vijendra

1 reply

Vijendra1
Adobe Employee
Vijendra1Adobe EmployeeAccepted solution
Adobe Employee
Sep 7, 2022 11:11 AM UTC

For any custom workflow for post generation, you need to add the last process step with process as "Finalize Post Generation" as shown in the figure

 

 

Thanks,

Vijendra

Translate