In the documentation it is said that when you create a new server-side application, you can start by copying the 'webapps/lcds' folder. I did that but then, Tomcat starts with some socket errors:
[LCDS]SocketServer 'my-rtmp-SocketServer' failed to pre-validate desired socket settings for BindSocketAddress: 0.0.0.0:2038
java.net.SocketException: Unrecognized Windows Sockets error: 0: JVM_Bind
[LCDS]SocketServer 'my-rtmp-SocketServer' failed to start.
flex.messaging.LocalizedException: SocketServer 'my-rtmp-SocketServer' cannot bind to accept client connections on port '2038' because another process has already bound the port. Please ensure that multiple endpoints across all applications are not configured to use this same port.
Am I doing something wrong?
Thanks,
Borek
Solved! Go to Solution.
Views
Replies
Total Likes
What is happening is that you are getting a port conflict for the socket-based NIO and RTMP endpoints used in the channel definitions in the services-config.xml file of your new web app. The issue is that you have endpoints bound to the same port in the LCDS web and in your new web app.
You can deal with this one of two ways:
Option 1: In that services-config.xml file, search on "RTMP" and "NIO" to find the channel definitions and change the port numbers to something slightly different than the ones used in the LCDS web app.
Options 2: Move the LCDS web app out of the picture so it doesn't get loaded, and just use a template for future web apps. If you aren't using it for any of your development, there is really no reason you have to load it.
I'll add a note about this to the documentation that talks about using the LCDS web app as a template.
Views
Replies
Total Likes
What is happening is that you are getting a port conflict for the socket-based NIO and RTMP endpoints used in the channel definitions in the services-config.xml file of your new web app. The issue is that you have endpoints bound to the same port in the LCDS web and in your new web app.
You can deal with this one of two ways:
Option 1: In that services-config.xml file, search on "RTMP" and "NIO" to find the channel definitions and change the port numbers to something slightly different than the ones used in the LCDS web app.
Options 2: Move the LCDS web app out of the picture so it doesn't get loaded, and just use a template for future web apps. If you aren't using it for any of your development, there is really no reason you have to load it.
I'll add a note about this to the documentation that talks about using the LCDS web app as a template.